﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
707	Revisit call to range-check for level 1B input (-inv) in ropp_pp_occ_tool	Stig Syndergaard	Stig Syndergaard	"When input bangle is less than -0.001 the range-check after reading in the bending angles gives -99999000 that cannot be handled by the processing. The result is that no refractivity is generated. One input example is:
ben_20210811_045421_SE6A_R005_O_3000_0010.nc.
