Opened 9 years ago

Last modified 9 years ago

#442 accepted defect

Occultations failing GPAC 2.2.0 pnc generation

Reported by: Stig Syndergaard Owned by: Stig Syndergaard
Priority: normal Milestone: DMI ROPP developments
Component: ropp_pp Version: 8.0
Keywords: Cc: hgl

Description

Five profiles failed the pnc generation in GPAC 2.2.0.

Three of them have large ionospheric scintillations which results in negative bangle_opt in some interval and then missing value for the refrac because ropp_pp_occ_tool in GPAC 2.2.0 is run with range check; in GPAC 2.3.0 we will run with --no-ranchk. Possibly these profiles should be caught in some QC, possibly in the dynamic error estimation part.

Two of them have very low CA SNRs. These could more easily be QC'ed, but it is not clear why they failed pnc generation. The profiles are cut off at both high and low altitude and the number of level1b and 2a data points are the same.

Investigate and implement better QC measures in ropp_pp_occ_tool

Attachments (5)

atmPhs_C001.2014.163.18.53.G32_2014.2050_nc (1.0 MB ) - added by Stig Syndergaard 9 years ago.
atmPhs_C006.2014.287.19.59.G11_2014.2860_nc (923.7 KB ) - added by Stig Syndergaard 9 years ago.
atmPhs_C001.2014.310.09.38.G31_2014.2860_nc (1.0 MB ) - added by Stig Syndergaard 9 years ago.
atmPhs_C001.2015.123.10.14.G17_2014.2860_nc (730.9 KB ) - added by Stig Syndergaard 9 years ago.
atmPhs_C001.2015.198.06.40.G04_2014.2860_nc (932.8 KB ) - added by Stig Syndergaard 9 years ago.

Change history (6)

by Stig Syndergaard, 9 years ago

by Stig Syndergaard, 9 years ago

by Stig Syndergaard, 9 years ago

by Stig Syndergaard, 9 years ago

by Stig Syndergaard, 9 years ago

comment:1 by Stig Syndergaard, 9 years ago

Status: newaccepted