FM does not write out pressure and geopotenital levels it generated internally

Reported by: frae Owned by: Huw Lewis
Priority: normal Milestone: 1.2
Component: ropp_fm Version: 0.9
Keywords: Cc:

Description

when running the ecmwf2ro_1d, the input geopotentials and pressure levels of the input background fields are just copied to the output file. Since ropp is internally generating pressure and geopotenial profiles from the input background fields, these should be written out. Otherwise the user will never know on which levels ropp actually calculated the bending and refractivity profiles unless he/she checks the code.

Change history (3)

comment:1 by Huw Lewis, 17 years ago

Owner: changed from frcm to Huw Lewis

To be fixed by additional call to ropp_fm_state2roprof in tool ropp_fm_bg2ro_1d (due for inclusion in ROPP v1.2). source:ropp_src/branches/dev/Share/r1182_frhl/ropp_fm/tools/ropp_fm_bg2ro_1d.f90

comment:2 by Huw Lewis, 17 years ago

Milestone: 1.11.2

comment:3 by Huw Lewis, 16 years ago

Resolution: fixed
Status: newclosed

v1.2 development code now updated to trunk for release [1594]. This includes call to ropp_fm_state2rprof in tool ropp_fm_bg2ro_1d. Ticket closed.