Description
We have this issue with a sharp "step" at 25 km in the raw bending angle O-B standard deviations. The cause is a change in the smoothing window between the wave optics processing and the geometrics-optics processing. The two windows can be set separately and one generally wants the WO-window to be smaller than the GO-window (or so I am told). One possible solution is to instead of abruptly changing from one size window to another at 25 km allow the window size to gradually transition from one to the other over a certain height interval.
Change history (6)
comment:1 by , 12 years ago
Milestone: | 7.0 → 6.1 |
---|
comment:2 by , 12 years ago
Milestone: | 6.1 → 7.0 |
---|---|
Owner: | set to |
Status: | new → assigned |
comment:3 by , 11 years ago
Milestone: | 7.0 → 8.0 |
---|
comment:5 by , 8 years ago
Milestone: | 9.0 → 10.0 |
---|
Still dunno what to do about this. Kent was looking at it briefly in the summer.
Moving milestone to ROPP10.0.
comment:6 by , 6 years ago
Resolution: | → duplicate |
---|---|
Status: | assigned → closed |
Solved by a gradual transition between GO and WO regimes in #610. Closing